High Resolution Spectrometer Features
Download PDF
  • Resolutions better than 0.1nm
  • Double the resolution over standard models
  • UV-VIS and High Resolution NIR options
  • Units are stackable for wide range analysis
  • Interchangeable Slit upgrade Options for HR Optics

 

Sample Spectra SpectraWiz Software Spectragryph Software Popular Accessories
       
 

The HR Spectrometer Series consists of our highest resolution spectrometers over the UV, VIS, & NIR wavelength range from 190-2300nm Compared to our standard BLUE-Wave series, our HR enclosures have twice the optical path providing double the resolving power. Applications include laser wavelength monitoring and characterization for tunable lasers/LEDs and other sources such as elemental emissions from plasma & LIBS spectroscopy. Also, optical sensing of temperature, pressure, & position are enabled via Bragg grating technology.

TEC and TEC-X2 Upgrade Capability – Optical housing includes sealed and isolated detector enclosure with specialized heat sink and air flow design for added stability and cool operation. Thermoelectric detector cooling improves the stability of the detector for lengthy measurements where thermal noise can distort and override signal. 1-stage TEC for -15 degrees and options for upgrade to the 2-stage TEC-X2 for -30 degrees below ambient; this increases instrument S/N drastically by reducing noise over 80% at long exposures.

Interchangeable Slit upgrade Options – Now available! Modification to your spectrometer’s optical bench input (new or old) allows access to exchangeable slits. Includes pack of 14, 25 50, 100, 200um slits. 14um for best resolution and 200um for high sensitivity applications. New slit locking technology means no hardware or screwdriver is required creating the most flexible spectrometer solution on the planet.

Ruggedized – The detachable spectrograph assembly and control electronics are protected inside a rugged metal enclosure, suitable for portable, process, lab, and field applications.

Onboard Memory with pre-set calibrations and spectrometer settings and snap shot memory to provide instantaneous spectral image from the highly sensitive CCD with 2048.

High Speed Electronic Interface can be attached directly to a computers USB port for high speed data transfer. Options for Wifi/ethernet communication available as well as other interfaces.



  CCD/PDA Detectors – Typical Response Predicted spectral resolution
HR Model
Wavelength Range (nm)
Grating
lines/mm
Gratin range
(nm)
nm/pixel dispersion
Slit - 25µm
nm resolution
Slit - 14µm
nm resolution
Slit - 7µm
nm resolution
HR-UV3/ UV3b
200 - 300 /
300-400
2400
100
0.048
0.21
0.14
0.07
HR-UV4
200 - 340
1800
140
0.068
0.3
0.2
0.1
HR-VIS
350 - 750
600
400
0.195
1.2
0.8
0.4
HR-NIR
500 - 900
600
400
0.195
1.2
0.8
0.4
HR-NIR2
900 - 1075
1200
175
0.085
0.8
0.4
0.2
HR-NIR3
750 - 850
1800
100
0.049
0.3
0.2
0.1
HR-NIR4
500 - 580
2400
80
0.039
0.12
0.08
0.04


LIBS Standard Resolution (SR) Spectrometer Models

LSR Models
Wavelength Range (nm)
Grating
lines/mm
Slit - 14µm
nm resolution
LSR-UV2
200 - 400
2400
0.2
LSR-VIS4
400 - 600
2400
0.2
LSR-VIS4a
600 - 800
1800
0.2
LSR-VIS3b
800 - 1000
1800
0.2


LIBS High Resolution (HR) Spectrometer Options

LHR Models
Wavelength Range (nm)
Grating
lines/mm
Slit - 7µm
nm resolution
LHR-UV3
200 - 300
2400
0.10
LHR-UV3b
300 - 400
2400
0.10
LHR-VIS3
400 - 500
1800
0.10
LHR-VIS3b
500 - 600
1800
0.10
LHR-VIS3c
600 - 700
1800
0.10
LHR-NIR3
700 - 800
1800
0.10
LHR-NIR2
800 - 975
1200
0.20


Near-Infrared High Resolution Spectrometer Models

DWARF-Star & RED-Wave Models
Wavelength Range (nm)
InGaAs Pixel #
Slit - 25µm
nm resolution
DS-NIR3-HR
1530 - 1605
512
0.40
DS-NIR3-HR
1500 - 1640
1024
0.40
DS-NIR2
1250 - 1575
512
1.3
DS-NIR2b
1250 - 1575
512
1.3
NIRX
1500 - 2200
512
2.8
NIRX
1500 - 2200
1024
1.4

Dynamic range: 2000:1 with 8 decades Dimensions: depends on specific model
Optical resolution: see model table – downto 0.1 nm Weight: 14 ounces (400 g)
Detector type: 2048pixel CCD, PDA opt. Power consumption: 100 mA @ 5 VDC
Detector range: 190-1600nm Interface: Parallel and USB-2
Pixel size: 14 x 200 µm Detector Integration: 1ms to 65s
Diffraction Gratings: Holographic & Ruled Slit size options: 5,10, 25, 50, 100, 200um
Grating g/mm: 300, 600,1200,1800, 2400 Stray light: <0.1% at 435nm;<0.05% at 600nm
Spectrograph: f/4, SymX-Czerny–Turner Fiber optic input: SMA905 0.22 NA single fiber
Order sorting filters: Integrated & High Pass Operating systems: Win XP, Vista, 7, 8, & 10
Signal to noise: CCD 1000:1, PDA 2000:1 Software included: SpectraWiz program & apps