[Spectroscopy Ninja]  
Spekwin32
About | Manual | News | Download | Copyright | Forum | Links | Testimonials | Contact | Imprint

Share this page on: share on Linkedin! . . . . Contact & Connect: academia.edu Tumblr: Haunted by spectra Facebook: Spectroscopy Ninja Flickr: just some pics LinkedIn: my professional self! Twitter: Spectroscopy Ninja Xing: another professional resume ResearchGate: my academic self my Google Plus youtube channel for Spectroscopy Ninja
 

Go to german version
About
Screenshots
Online-Manual
History
News
Download
License Order
Copyright
Links
User Forum
Testimonials
Contact

Just released!
The brand-new, top-modern
successor software for Spekwin32

Spectragryph 1.0

History / Versions of Spekwin32

History of Development:

  • The original software named Spekwin (16bit version) was developed in the Daltrozzo group at the Universität Konstanz in 1997-1998 by Dr. Claus Vielsack with DELPHI1. Most recent 16bit version (for Microsoft Windows 3.1) is Version 1.09 from 1999.
  • An early attempt to create a software for spectra display was undertaken by Dr. G. Kollmannsberger with TURBO PASCAL (DOS program tpbld.exe, until 1994).
  • Since 1999, further development is pursued by me. At present there is the 32bit-Version SPEKWIN32 (developed with DELPHI 4) with enhanced functionality and much increased working speed for some functions. A big part of the work took place during my Ph.D. at the Daltrozzo group from 2000-2005. Development speed went down somewhat afterwards. Since 2010, many new functions have been introduced.
Period Language, System Name Programmer
? - 1994 TurboPascal, DOS tpbld Dr. G. Kollmannsberger
1997-1998 Delphi 1, 16bit-Windows Spekview / Spekwin Dr. Claus Vielsack
1999- now Delphi 4, 32bit-Windows Spekwin32 Dr. Friedrich Menges

 

Versions:

  • Version 1.72
    MAJOR IMPROVEMENTS:
    Reading of OceanOptics *.procspec files
    Reading of *.jws files from JASCO spectrometers
    Reading of *.spc files from SHIMADZU UV-1600, UV-1800 spectrometers
    Reading of *.wls files: VWR UV-1600PC spectrometer, software: M.wave professional
    Reading of binary *.sp files created with PECSS software (Perkin Elmer Lambda 2, Lambda 9, etc.)
    Reading of Unicam U450 spectra (after renaming to *.csv)
    Reading of Ascanis Lambda-SPX/ VISIONlite spectra (*.dsp)
    Reading of StellarNet SpectraWiz spectral files (*.abs, *.trm, *.ssm, *.irr, *.lib)
    Reading of USGS Spectral Library data (*.asc)
    Strongly improved reading of ASCII data in *.csv file format, automatic detection of axis types, recognition of xyxyxy vs. xyyyyy type.
    Saving of *.rruff files for RRUFF/ CrystalSleuth database
    Automated Peak labeling function with possibility to label only "prominent" peaks ("prominence" parameter adjustable)
    "Spectroscope View" transforms spectrum into visual appearance as seen through a table spectroscope.
    Accept data pasted from the clipboard and directly convert to plot
    Reading of unknown binary files into Excel template, to reveal internal structure (still experimental)
    Reading of EEMs (excitation emission matrix) with excitation wavelengths from Excel or *.csv files
    Attribute excitation wavelengths to series of fluorescence spectra, replace legend text with these numbers
    Automated removal of first & second order Rayleigh scatter peaks and solvent Raman peaks for EEM data
    Subtract a Blank dataset from an EEM
    Switch EX/EM direction for EEM plot, export EEM plot to Clipboard
    Show average value together with integral value during Integration function
    Show peak bandwidth (FWHM) together with found peaks. Variable Threshold for peak detection.
    "Inverted peak finding", e.g. for transmission maximum of bandpass filters.
    Calculate Raman Shift spectrum from a wavelength spectrum + laser wavelength.
    "Advanced Smoothing" options: with adjustable intervals for "Moving box" (different box shapes), "Savitzky-Golay" (2nd to 5th polynomials), "Percentil filter"
    "Advanced Baselining" options: interactive mode for linear, adaptive, scattering baseline types
    Batch Export into spc, dx and csv files. Single spectrum or multiple spectrum file possible. Filenames and filepath configurable.
    Optional setting: multiple instances

    MINOR IMPROVEMENTS/ BUG FIXES:
    Changeable size of FileOpen/ FileSave windows
    Improved reading of JCAMP-DX of reflectance type and with ##YUNITS=(micromol/mol)-1m-1 (base 10)
    Reading of *.fak files in UNICODE format
    Replaced occurences of "Delete" by "Remove" in many places
    Resolved bug with occasional crashing while starting Spekwin32 by clicking associated file type
    Bugfix for Avantes files (software v7.2) with NULL character contained
    Save for Gnuplot: fixed problem for x axis ending with "0" (wavenumbers), adapted syntax for Gnuplot v4.6
    Corrected reading of Raman *.spc files with inverted order and type "uneven"
    Prevent reading of Bruker OPUS *.sp files when opening PerkinElmer files
    Resolved bug while reading of certain type of mixed ASCII/binary *. sp files (Perkin Elmer)

    v1.72.1
    Settings from options dialog and "most recently use files" list are individually saved for each user
    Improved behaviour for "limited user accounts", no more writing to program folder

    Improved reading of JASCO *.jws files, greater range of JASCO files
    V1.72.2
    Normalization by area
    Reading of THERMO Nicolet OMNIC *.spa spectral files
    Reading of ColVisTec *.wl & *.dat spectral files
    Further improved reading of JASCO *.jws files, recognizes reflectance & RamanShift

  • Version 1.71
    Reading of THERMO Galactic/ GRAMS spc multifiles possible.
    v1.71.1
    Reading of fully binary and mixed ASCII/binary PERKIN ELMER data files possible.
    v.1.71.3
    Reading of csv files from several different spectrometers.
    Professional installation file.
    v.1.71.4
    Saving of JCAMP-DX files possible (finally!).
    Saving of multifile multiformat csv files possible. Spekwin32 will also read those files correctly.
    Reading of csv files from the WTW photoLab spectral software.
    In menu item
    "General", the edit box "wavelength" and the function "edit legend texts" are now available.
    Minor cosmetic changes in the GUI.
    User status will be displayed on program start. New menu item: "User Status"
    Registration of Spekwin32 spv file type with Windows during installation (sorry SPSS users, the Spekwin32 spv file type exists much longer). Registration of spc I/O dll during installation makes life easier for Windows Vista users.
    v.1.71.5
    Calculation of 1. - 4. derivative (smoothing included), expanded menu item Derivative.
    "Find Peaks" und "'Concentration" possible with transmission mode.
    Reading of JCAMP-DX spectra from Tecan's Magellan software; Bugfixes with saving of JCAMP-DX files.
    Improved installation & performance for users without admin permissions.
    "Counts" possible as y axis type with csv files.
    Spectral type "Raman" preserved on reading of fak, spc & spe files.
    Dialog for unknown axis types on reading of fak files. Bugfixes with reading of fak files.
    Suggestion of reasonable values for spectrum borders with
    Cut off Spectrum Part for wavenumber scale.
    Default size for axes captions and legend texts increased from 8 to 10 points.
    v1.71.6
    Calculate film thickness from reflection spectrum.
    Perform calculations (addition, subtraction, multiplication, division) on all spectra simultaneously.
    Copy spectral data directly to clipboard.
    Better Win 7 compatibility.
    Reliably working on systems without installed printers.
    Reading of Beckman Coulter DU 600/7000 binary and ASCII files.
    Reading of Thermo Electron Helios csv files.
    Correct reading of Perkin Elmer 850 csv file header.
    Reading of Perkin Elmer reflectance files.
    Reading of HP Chemstation dx files.
    Further improvement of reading *.fak files (blank as delimiter).
    Improved handling of reflectivity as y axis type.
    Optionally replace legend text by filename (menu item: General).
    Legend won't disappear on window resize or reshift (implemented for top and left border).
    v1.71.6.1
    Fixed the aspect ratio of picture files when exporting as gif/png/tif
    Fixed the reading of *.fak files with wavenumbers inside
    Improved reading of *.spc files containing multiple spectra
    Corrected smoothing of spectra with large x-axis step width
    Reading of Beckman DU *.scn files with transmittance y-axis type
    Reading of JCAMP-DX files containing multiple spectra
    Reading of Horiba Datamax *.prn files
    "RamanShift" as independent x-axis type. automatic detection and display
    (formats: rruff, spc, spe, sp, fak, csv)

  • Version 1.70
    Minor Bugfixes.
    Works correctly on systems with no printer installed.
    List of most recently used files works now.
    "Help" button on all dialogs, will open corresponding manual file.
    New x axis type "µm" selectable.
    Minor bugfixes with JCAMP-DX files.
    Bugfix with saving spectra as graphics files.
    New menu item "
    Transmission/Reflectance": Calculation of transmittance / reflectance spectra from two spectra after T=I/I_0.
    Bugfix with menu item "Display Values".
    XP-style enabled GUI.

  • Version 1.69
    Import of sp spectra of the Perkin Elmer DOS software CFS (LS-3b, -4b und -5b fluorescence spektrometer).
    Reading of Jobin Yvon Raman .spc files works now

    Menu item "General": Changing all legend titles in one window, with Search&Replace

    Display limit of 65536 points per spectrum removed.
    Increased reading speed with *.fak, *.ggg and Avantes files.
    Changed y axis file type "transmission" to "transmittance" for better compliance with IUPAC standards.
    Bugfix with reading/writing of Galactic *.spc-files: registration of DLL works now with all system languages.
    Bug fixed with reading of Perkin elmer IR spectra, bug fixed in menu item
    "Information".
    Flipping of x axis.
    Reading of Roper Scientific / Princeton Instruments WinSpec/WinView binary files (*.spe).
    Two bug fixes in English version.
    Adjustable step width of x values for writing of Spekwin32 ASCII files (*.dat) in Configuration window.
    Bug fixed with reading of Galactic *.spc spectra.
    Reading of Spekwin32 ASCII files (*.dat) reworked, x axis type will be automatically recognized.
    Uniform look of OK and Cancel buttons in all windows.
    Bugs fixed with Baseline Correction and Cut off Spectrum Part.
    Overhauled saving as ASCII file (*.dat) . X values now linear in the current x axis type.
    Treatment of x and y axis types revised. Axis types will be selected mostly automatically depending on spectral file type..
    Reading of Perkin Elmer spectra with wavenumbers possible (Perkin Elmer Raman spectrometer).
    Spectra coming in wavenumbers (Raman & IR) will not be interpolated any more into wavelength scale. Therefore faster and more accurate.
    New Spekwin32 file format. Not compatible with Spekwin32 versions prior to version 1.69.2
    New display options "normal" and "Gradient" in menu item "2D-Spectrum (EEM)".
    Option "Label each second Tick" in menu item "Axes" will not be activated by default any more with wavelength axis type.
    New x-axis type: Display as "electron volts" can be selected in menu item "Axes".
    New Help window with link to homepage and to the locally saved manual (in Spekwin32 subfolder /manual).
    Opening window no longer necessary with Milton Roy spectra.

  • Version 1.68
    Calculation of excitation spectra possible for all spectra with assigned wavelength (at present: only Perkin Elmer fluorescence spectra)
    Revised writing and reading of Spekwin32 ASCII files.
    Reworked reading of JCAMP-DX spectra, made it more fault-tolerant.
    Setting of x axis boundaries now optional in menu item "Axes"
    Spectral display rescale after normalization and reading of new spectra.
    Revised menu item "Find Peaks": direct access of spectra, peaklist can be copied.
    Reading of Avantes Avasoft spectra (*.trt, *.tat, *.ttt, *.tit).
    Menu item "Low Temp. QY" now working
    Bugs fixed: display problems with y values above 300, errors with division of spectra with very small y values, wrong scaling of y axis ticks with y values above 500000.
    Menu "Axes" moved into menu "Plot/Options" as menu item.
    Setting colour scale, line width and line type back to default with menu item "Standard Lines&Colours".
    Menu item "Information" gives Information about individual spectra.
    New Spekwin32 file format. Not compatible with Spekwin32 versions prior to version 1.68.1
    Colour scale not fixed any more, colour/ line width/ line type are connected to the spectra, even when the order is changed
    Relative line width can be assigned to each spectrum individually in menu item "General". Is saved in Spekwin32 files.
    Changing of global line width as separate menu item. Used to be in menu item "General".

  • Version 1.67
    Smaller bug fixes, code cosmetics.
    Bug resolved with changing concentration in e / log(e) mode.
    Showing list of most recently used *.spv files in "File" menu.
    Spectra from *.spv files are read with their saved colours and line types.
    Reading and writing of Galactic *.spc spectral files.
    Menu item "2D Spectrum (EEM)": variable window size, logarithmic scaling.
    Menu item "Sort" sorting by wavelength works now.
    Reading of HP/Agilent 8453 *.csv files.
    Bugfix with saving of FTIR spectra as ASCII files (problem was: zero as last wavenumber value).
    Measuring temperature is shown and can be modified in menu item "General".
    Changed colour order: replaced yellow by orange for better visibility.

  • Version 1.66
    Bugfix with spike removal (program crashed, when "Delete Original" was checked and "Treat all Spectra" was unchecked)
    Reading of Cary 50 multiple spectrum files (*.csv).
    Level for Spike Removal can be set in menu item "Configuration".
    Reading of Spekwin32 ASCII files (*.dat).
    Saving graphics as PNG (*.png), Size: 1350x900 pixels.
    New Menu item "2D Spectrum (EEM)": Display of two-dimensional fluorescence spectra from fluorescence or excitation spectra. Example: 2d_beispiel.zip (315KB)
    Saving graphics as TIFF (*.tif), Size: 1350x900 pixels.
    New menu item "Configuration" for setting of many program options. Settings will be loaded autzomatically on program start.

  • Version 1.65
    Greatly improved support of JCAMP-DX file format (for description see here & there). Many UV/VIS and IR spectral files in 4.24 standard will be read (except DIFDUP coded files).

  • Version 1.64
    Bugfixes.
    Setting of x axis boundaries works again.
    New menu item "Spectra Averaging":calculates the average of any number of spectra.

  • Version 1.63
    "staircase bug"still remaining until version 1.62.2
    Error messages are written to a log file ("error.log" in folder Spekwin32).
    Menu item "General": bigger line width for selected spectrum.
    Changed colour scale: repeated cycling of 14 colours.
    "Division by zero" prevented at different locations.
    Eliminated two bugs within "
    Save for Gnuplot".
    Menu item "
    Sort" works now like expected.
    Menu item "
    Concentration": layout reworked.
    Menu item "
    Integration": process might be canceled.
    Menu "
    Gaussfit" layout reworked, fitting routines working more reliable.

  • Version 1.62
    Increased speed with function "
    Smooth" by factor 20.
    Redrawing of spectra in the graph window with increased spead.
    All edit boxes for numbers will accept point and comma as decimal separator, independent from regional setting.
    Menu item "
    Y Constants" accepts real-valued exponents for calculations with x / y axes.
    New menu item "
    Sort": order of spectra changeable manually or sortable automatically.
    Still fighting against "staircase bug".
    Reworked "
    Save for Gnuplot"
    Info window links to Spekwin32 website.
    Spekwin32 gets started by double clicking on linked files in Windows Explorer.
    Drag&Drop of Spekwin32 readable files possible.

  • Version 1.61
    Program file size decreased by 100kB.
    Menu item "
    General": changed tab order, fixed bug with entering concentration values
    Display of second x axis with "
    Save for Gnuplot".
    Menu item "
    Y Constants": calculations with all spectra of one type.
    Reading of Cary 50 files (*.csv) with included log.

  • Version 1.60
    Second x axis can be displayed at upper border of graph (reciprocal scale).
    Fixed bug with Windows system time.
    Fixed bug with Save (ASCII format).
    Scaling of x axis in wavelength scale now error free.

  • Version 1.59
    Legendentext von Spekwin-erzeugten Polarisationsgradspektren verändert.
    Skalierung beim Einlesen von *.g-Spektren angepaßt.
    Entspiken überarbeitet: bessere Interpolation der Spikes.
    Automatische x-Achsen-Skalierung verbessert, vorgegebene Achsengrenzen im Achsendialog werden genau eingehalten.
    "Treppenbug" beseitigt (incl. zwei Nachwehen).
    Bug bei Polarisationsgradberechnung beseitigt.
    Menüpunkt "Auswahl löschen": Auswahlmöglichkeit für Löschen aller Spektren eines Typs.
  • Version 1.58
    Skalierung der y-Achse verbessert (mehr Tics im Bereich bis 0,2).
    Legendentext für berechnete Gesamt- / Polarisationsgradspektren verbessert.
    Berechnung aller Gesamt- / Polarisationsgradspektren aus den geladenen Spektren (nur *.ggg-Typ) auf einmal möglich.
    Bug beim ASCII-Speichern behoben.
    Menüpunkt "Ausschneiden": Zusatz "Teilspektrum" optional, Grenzen werden gespeichert, Auswahlmöglichkeit für Ausschneiden aller Spektren eines Typs, Option zum Löschen der Originalspektren.
  • Version 1.57
    Spike-Entfernung überarbeitet, "rückwärts entspiken" möglich.
    Einblenden eines Gitters möglich.
    Geänderte Bildformate: 1350x900-GIF, 1000x680-BMP.
    Shortcuts überarbeitet.
    Format der *.gas-Spektren korrigiert (richtiges Zeilenende).
    Bei FQ-Berechnung "spezial" ist bei gleicher Anregungswellenlänge kein geladenes Lampenspektrum mehr notwendig.
    Bei *.gkl- und *.gpo-Spektren wird Meßtemperatur und Spektrentyp in Legende angezeigt.
    Bei *.ggg-Spektren wird die Meßtemperatur in der Legende angezeigt.

  • Version 1.56
    Programm startet auch auf einem System ohne installiertem Drucker.
    Speichern als WMF jetzt als Option in Speichern-Dialog.
    Iconleiste verändert.
    Neue Grafik-Formate zum Abspeichern: Export als GIF (1200x900 Pixel) und Bitmap (1024x768 Pixel) möglich.

    Version 1.55
    Spekwin32 piepst jetzt hier und da und kann Musik machen (Spektren abspielen).
    Beispiele: "Alle meine Entchen" , "Bourrée"

  • Version 1.54
    Hilfetext geändert, Hinweis auf Webseite.
    Neues FQ-Spektrum wird immer rot gezeichnet.
    Werte aus dem Peakdialog sind kopierbar.
    Entfernung von Spikes möglich! (v. a. für CCD-Spektren). Sehr elaboriert!

  • Version 1.53
    Stürzt nicht mehr ab, wenn Werteleser mehrmals gestartet wird, ohne ihn vorher zu beenden.
    Export als *.gas eingebaut.

  • Version 1.52
    Ein "." im Dateipfad verhindert nicht mehr das Einlesen von Spektren.
    Einlesen von Perkin Elmer-Spektren konsistent für alle Intensitäten.
    Alle [Help]-Buttons entfernt.
    Darstellung unabhängig von Systemeinstellung große/kleine Schriftarten.
    Einlesegeschwindigkeit drastisch erhöht für *.ggg-Spektren.
    Editierfelder für x- & y-Achsenbeschriftung.

  • Version 1.51
    Berechnung von Gesamtspektren (g=2x+y).
    Polarisationsgradspektrum berechnen korrigiert.

  • Version 1.50
    Dies & Das.
    Ländereinstellung des Systems für Dezimaltrenner wird abgefragt.
    Erkennt alle Perkin Elmer-Spektren (*.sp und *.dx), zumindest alle die mir zur Verfügung standen.
    "Jubiläumsversion", umbenannt in Version 1.50 (statt 1.0.50).

  • Version 1.0.49
    Pol.gradspektren werden richtig skaliert im Gnuplot.
    Neuer Legendentext für *.ggg-Spektren (enthält Spektrentyp, Anr./Det.wellenlänge).
    Geändertes Dateiformat der *.g-Spektren. Beide werden eingelesen.

  • Version 1.0.48
    Transmissionsspektren vom Cary 50 werden erkannt und als Extinktion eingelesen.

  • Version 1.0.47
    Parameter für Erregerspektren bleiben erhalten (Bereich, Schrittweite, Löschbox).
    Anzeige der x-Achsengrenzen auch bei Wellenzahlen richtig (Bug aus 1.0.42).
    effekt. Ext.-Berechnung ohne geladenes Lampenspektrum möglich (Bug aus 1.0.45 behoben).
    Lampenkurve mit Schrittweite ungleich 1 möglich.

  • Version 1.0.46
    Filterindex von [Datei Öffnen] umgestellt.
    Einlesen von Original-DMS-Spektren möglich (Binärformat *.dms).

  • Version 1.0.45
    Speicherlecks gestopft und diverses Fein-Tuning (fast alle Forms werden dynamisch erzeugt).
    effekt. Ext. auch ohne Lampenspektrum möglich.

  • Version 1.0.44
    Sanduhr bei Glätten, Drucken, Einlesen von *.dxi und *.g .
    Druckbild völlig druckerunabhängig.
    y-Achsenbeschriftung sichtbar in WMF und Druckbild.
    y-Achsenbeschriftung senkrecht.

  • Version 1.0.43
    Automatische Skalierung in Wellenzahlskala verbessert.
    Reskalierung mit rechter Maus so angepaßt, daß y-Achse möglichst bei Null beginnt.
    Spektren beliebig auswählbar bei [Löschen]/[Auswahl].

  • Version 1.0.42
    Anzeigen und Verändern der x-Achsenbegrenzung im Achsendialog.
    Automatische Aktivierung von [jeder zweite Tick] beim Umstellen auf Wellenzahlen.
    Rechter Mausklick zeichnet nur noch einmal neu.

  • Version 1.0.41
    Einheit des Fluoreszenzschwerpunkts je nach Achsentyp.
    Einheitl. deutsche Menüs.
    Anzeige der Linienbreite im [Allgemein]-Dialog, Spektren direkt anwählbar.
    Tastatur-Shortcuts.

  • Version 1.0.40
    y-Achsenskalierung wird mit abgespeichert beim Export für Gnuplot.
    Glätten abhängig vom Wellenlängenintervall der x-Werte des Spektrums.
    Schnelleres Einlesen von Dateien im UNIX-Format (*.g, *.ggg).
    Verlaufsanzeige in Statusleiste eingefügt, aktiv beim Glätten und Einlesen von *.g-Spektren.

  • Version 1.0.39
    Einlesen von *.g-Spektren überarbeitet.
    Einlesen von *.ggg-Spektren möglich.

  • Version 1.0.38
    Info- und Hilfefenster verändert
    Gaussfit angepaßt.
    Diverse Bugs ausgemerzt.

  • Version 1.0.37
    Einlesen von Cary 50 - Spektren (*.csv), mit Interpolation.

  • Version 1.0.36
    diverse Änderungen.
    Neues Info-Fenster.
    Bandpaß mit integrierter Erregerintensität.
    Berechnung der wellenlängenabhängigen Quantenausbeute ("1D-FQ" im FQ-Dialog).

  • Version 1.0.35
    Bugfix.

  • Version 1.0.34
    Einlesen von Spektren (ASCII) des PE LS-50b - Spektrometers (*.sp)

  • Version 1.0.33
    Fehler bei Korrektur der Erregerintensität behoben.
    FQ-Berechnung aufgeteilt in "normal" und "spezial". "Spezial" liest die Extinktionswerte aus dem angegebenen Absorptionsspektrum aus und berechnet mit dem angegebenen Bandpaß die effektive Extinktion.

  • Version 1.0.32
    Hintergrundfarbe weiß statt grau.
    Berechnung der effektiven Extinktion verändert.

  • Version 1.0.31
    Filter für Speichern als *.spv heißt Spekwin (statt Spekview).
    Neue Farbreihenfolge der angezeigten Spektren (14 versch. Farben, alle weiteren werden schwarz angezeigt).
    Kopieren in die Zwischenablage und Speichern als WMF funktioniert mit allen Linienarten.

  • Version 1.0.30
    Fehler bei Korrektur der Erregerintensität und Berechnung der Erregerspektren behoben.
    Maximum der anzeigbaren Spektren von 255 auf 65526 erhöht.
    Speichern als *.spv/*.dat wird über den Filter gesteuert, unabhängig von der Dateierweiterung die beim Dateinamen steht.

  • Version 1.0.29
    Einlesen von *.prn-Spektren (CCD-Kamera) im ASCII-1 - Format funktioniert richtig.
    Problem mit Null als y-Wert beim Speichern für Gnuplot behoben.
    Polarisationsgradspektrum berechnen funktioniert richtig.

  • Version 1.0.28
    Berechnung von Erregerspektren eingebaut.

  • Version 1.0.27
    Korrektur der Erregerintensität eingebaut. Speichern als ASCII gibt die Matrix zur Anzeige als zweidimensionales Spektrum (z. B. mit Origin).

  • Version 1.0.26
    Überarbeitung von "Speichern für Gnuplot": Auswahl möglich zwischen farbigem und S/W-Ouptput als EPS. Einfügen zusätzlicher Gnuplot-Befehle möglich.

  • Version 1.0.25
    Alle Formulare neu überarbeitet, => einheitlicher Look der Dialoge.

  • Version 1.0.24
    Berechnung von Polarisationsspektren aus x- und y-polarisierten Spektren möglich.

  • Version 1.0.23
    "Speichern für Gnuplot" eingebaut, mit:
    automatischer Abfrage von x-/y-Achsentyp
    Anzeige der zweiten y-Achse, wenn Pol.gradspektrum enthalten ist
    Änderungen vor dem Speichern möglich (Achsentyp/Legendenposition)
    enthält Gnuplot-Anweisungen für Export als EPS-Datei durch Gnuplot.

  • Version 1.0.22
    Beim Speichern als ASCII-Datei (*.dat) wird immer Wellenlänge und Wellenzahl in den ersten beiden Spalten abgespeichert.

  • Version 1.0.21
    Zweite y-Achse wird automatisch gelöscht, wenn kein Pol.gradspektrum mehr vorhanden.

  • Version 1.0.20
    Einlesen der Spektren vom Perkin Elmer FTIR 1760X verbessert (Behandlung negativer Transmissionen).

  • Version 1.0.19
    Aminco-Spektren (*.spe) werden richtig eingelesen.

  • Version 1.0.18
    Spektren des NIR-Fluoreszenzspektrometers (*.dio) werden richtig eingelesen.

  • Version 1.0.17
    Christians "multiple Fluospektren" (*.g) werden eingelesen.

  • Version 1.0.16
    Druckroutine überarbeitet, druckt nur noch einmal.

  • Version 1.0.15
    Spektren in Wellenzahlen werden richtig abgespeichert.

  • Version 1.0.14
    Einlesen von IR-Spektren (Perkin Elmer FTIR 1760X).

  • Version 1.0.13
    Hintergrundfarbe des Grafikfensters veränderbar.

  • Version 1.0.12
    Alte und neue Spekwin-Spektren (*.spv) werden richtig eingelesen.

  • Version 1.0.11
    Druckroutinen bearbeitet.

  • Version 1.0.10
    Skalierung des Legendentexts beim Drucken wieder richtig.

  • Version 1.0.9
    y-Achsenbeschriftung stimmt wieder.
    Speichern als WMF funktioniert wieder.

  • Version 1.0.8
    Kopieren in die Zwischenablage funktioniert wieder.

  • Version 1.0.7
    Linienbreite verstellbar (nur für alle Spektren gleichzeitig).

  • Version 1.0.6
    Interne Stringbehandlung verändert. Probenname von MiltonRoy-Spektren wird richtig eingelesen.

  • Version 1.0.5
    Statusleiste eingefügt. Enthält drei Bereiche:
    1. Anzahl der Spektren
    2. verschiedene Meldungen
    3. stets aktueller Bildschirmleser

  • Version 1.0.4
    Interpolation beim Einlesen von MiltonRoy-Spektren. Die Spektren stimmen jetzt perfekt mit dem Original überein.

  • Version 1.0.3
    Berechnung der effekt. Extinktion verbessert.

  • Version 1.0.2
    CCD-Spektren (*.prn) im ASCII-1 - Format werden eingelesen.

  • Version 1.0.1
    Icons eingefügt für die wichtigsten Menüpunkte.
    neues Startfenster.
    neuer Name: Spekwin32 .
    neues Programm-Icon.

  • Version 1.0.0
    erste mit Delphi 4 compilierte 32bit-Version von Spekwin.
 © 2001-2015: Dr. Friedrich Menges. Letzte Änderung: 24.02.2017